  "company": {
    "name": "Brackmoor Foods",
    "site": "Pendle Road Plant",
    "address": "1840 Pendle Road, Twin Falls, ID 83301",
    "phone": "(208) 555-0148"
  },
  "wo": {
    "number": "WO-2026-014872",
    "url": "https://cmms.brackmoor.example/wo/WO-2026-014872",
    "type": "Corrective",
    "priority": "2 · High",
    "status": "Completed",
    "requestedBy": "L. Moreau, Line 2 operator",
    "requestedAt": "2026-11-11T22:15:00-07:00",
    "plannedStart": "2026-11-12T06:30:00-07:00",
    "dueDate": "2026-11-12T14:00:00-07:00",
    "completedAt": "2026-11-12T12:05:00-07:00",
    "printedAt": "2026-11-12T13:20:00-07:00",
    "costCenter": "3120 Line 2 Processing",
    "problem": "Steady drip of hot CIP caustic at the mechanical seal of the supply pump, about 1 drop per second, seen on the operator round during the night shift. CIP duty switched to standby pump P-2105. No product contact.",
    "workPerformed": "Replaced the cartridge seal, casing O-rings and gasket, and the coupling element. Seal faces worn and scored, no damage to shaft sleeve or impeller. Alignment 0.03 mm offset after reassembly. Run test on water at 3 bar for 15 minutes: no leak, vibration 2.1 mm/s."
  },
  "asset": {
    "tag": "P-2104",
    "description": "CIP supply pump, Line 2 kettles",
    "location": "PRP / Processing / Line 2 / CIP skid 2",
    "equipmentClass": "Pump, centrifugal, sanitary",
    "model": "Marvane Fluid Systems SC-50/32, 7.5 hp",
    "serial": "SC5032-118406",
    "criticality": "A · High",
    "maintainableItem": "Mechanical seal"
  },
  "safety": {
    "procedure": "ECP-P2104 rev. C",
    "lockout": "Group lockout, lockbox LB-07",
    "hazards": "Caustic solution 2% NaOH at up to 80 °C, residual line pressure, rotating equipment, 480 V motor",
    "isolations": [
      {
        "point": "E1",
        "energy": "Electrical, 480 V AC",
        "device": "MCC-2B, bucket 07 breaker",
        "method": "Open, lock and tag",
        "lock": "L-0417",
        "verified": true
      },
      {
        "point": "C1",
        "energy": "Chemical, hot caustic",
        "device": "Suction valve V-2104S",
        "method": "Close, lock with valve cover",
        "lock": "L-0418",
        "verified": true
      },
      {
        "point": "C2",
        "energy": "Chemical, hot caustic",
        "device": "Discharge valve V-2104P",
        "method": "Close, lock with valve cover",
        "lock": "L-0419",
        "verified": true
      },
      {
        "point": "S1",
        "energy": "Stored pressure and heat",
        "device": "Casing drain V-2104D",
        "method": "Open to drain, 0 bar at PI-2104",
        "lock": "Tag T-0233",
        "verified": true
      }
    ],
    "permits": [
      {
        "name": "Line break",
        "ref": "LB-2026-0388"
      },
      {
        "name": "Hot work",
        "ref": "Not required"
      },
      {
        "name": "Confined space",
        "ref": "Not required"
      }
    ],
    "ppe": "Chemical splash goggles and face shield, neoprene gauntlet gloves, chemical apron, safety shoes, hearing protection, hairnet"
  },
  "tasks": [
    {
      "step": 10,
      "text": "Confirm with the Line 2 supervisor that CIP runs on standby pump P-2105.",
      "done": true
    },
    {
      "step": 20,
      "text": "Apply group lockout per ECP-P2104 at the four points above. Try the local start button, then return it to OFF.",
      "done": true
    },
    {
      "step": 30,
      "text": "Drain the casing through V-2104D and confirm 0 bar at PI-2104 and a casing below 40 °C.",
      "done": true
    },
    {
      "step": 40,
      "text": "Remove the coupling guard, the coupling element and the pump casing.",
      "done": true
    },
    {
      "step": 50,
      "text": "Replace the cartridge seal and all EPDM O-rings. Inspect impeller, shaft sleeve and casing.",
      "done": true
    },
    {
      "step": 60,
      "text": "Reassemble. Laser-align the shaft to within 0.05 mm offset.",
      "done": true
    },
    {
      "step": 70,
      "text": "Release the lockout per ECP-P2104: tools removed, all workers clear, affected employees notified. Check rotation with the operator.",
      "done": true
    },
    {
      "step": 80,
      "text": "Run on water at 3 bar for 15 minutes: no leak at the seal, vibration below 4.5 mm/s.",
      "done": true
    },
    {
      "step": 90,
      "text": "Hygiene clearance: tool and part count, area cleaned, QA release before CIP returns to service.",
      "done": true
    }
  ],
  "labor": [
    {
      "craft": "Millwright",
      "technician": "D. Mensah",
      "estimatedHours": 4,
      "actualHours": 4.5,
      "rate": 68
    },
    {
      "craft": "Millwright apprentice",
      "technician": "J. Halloran",
      "estimatedHours": 4,
      "actualHours": 4,
      "rate": 41.5
    },
    {
      "craft": "Electrician",
      "technician": "R. Ibarra",
      "estimatedHours": 1,
      "actualHours": 0.75,
      "rate": 72
    }
  ],
  "parts": [
    {
      "partNo": "30-1182-04",
      "description": "Cartridge mechanical seal 32 mm, SiC/SiC, EPDM",
      "bin": "A-14-03",
      "qty": 1,
      "unit": "EA",
      "unitCost": 584
    },
    {
      "partNo": "30-1190-11",
      "description": "O-ring kit, EPDM, FDA 21 CFR 177.2600",
      "bin": "B-02-07",
      "qty": 1,
      "unit": "KIT",
      "unitCost": 36.5
    },
    {
      "partNo": "30-1201-02",
      "description": "Casing gasket, PTFE",
      "bin": "B-02-09",
      "qty": 2,
      "unit": "EA",
      "unitCost": 11.4
    },
    {
      "partNo": "41-0450-00",
      "description": "Coupling element, jaw type, size 28",
      "bin": "C-05-01",
      "qty": 1,
      "unit": "EA",
      "unitCost": 48.9
    },
    {
      "partNo": "60-0012-07",
      "description": "Lubricant, NSF H1, 400 g cartridge",
      "bin": "D-01-02",
      "qty": 1,
      "unit": "EA",
      "unitCost": 13.75
    }
  ],
  "failure": {
    "detection": "Casual observation (operator round)",
    "mode": "ELP · External leakage, process medium",
    "mechanism": "2.4 · Wear",
    "cause": "3.4 · Expected wear and tear",
    "activity": "Replace",
    "downStart": "2026-11-12T06:40:00-07:00",
    "downEnd": "2026-11-12T12:15:00-07:00",
    "downHours": 5.58,
    "productionLossHours": 0
  },
  "signoff": [
    {
      "role": "Technician",
      "name": "D. Mensah",
      "date": "2026-11-12T12:05:00-07:00"
    },
    {
      "role": "Maintenance supervisor",
      "name": "K. Whitcombe",
      "date": "2026-11-12T12:40:00-07:00"
    },
    {
      "role": "QA hygiene release",
      "name": "S. Patel",
      "date": "2026-11-12T12:15:00-07:00"
    }
  ]
}